BGXJD - X-PANDO PIPE JOINT COMPOUND

  • MSDS: BGXJD
  • Manufacturer: X PANDO PRODUCTS CO
  • Product Name: X-PANDO PIPE JOINT COMPOUND
  • National Stock Number: 8030-00-274-4170
Product Identification

Product ID:X-PANDO PIPE JOINT COMPOUND
MSDS Date:10/31/1986
FSC:8030
NIIN:00-274-4170
MSDS Number: BGXJD

Responsible Party
X-PANDO PRODUCTS CO.
500 SOUTHARD STREET
TRENTON, NJ 08638
US

Emergency Phone: 609-394-0150 (DAY)

Info Phone: 609-394-0150 (DAY)

Preparer: TIMOTHY J. COLLITON

Cage: 95534

Contractor
X-PANDO PRODUCTS CO.
TRENTON, NJ 08638 US

Telephone: 609-394-0150 (DAY)

Cage: 95534

Ingredients

MAGNESIUM OXIDE

CAS: 1309-48-4

RTECS: OM3850000

OSHA PEL 15 MG/M3 PARTICULATE

ACGIH TLV: 10 MG/M3;TDUST; 9293


GRAPHITE, NATURAL

CAS: 7782-42-5

RTECS: MD9659600

OSHA PEL 15 MPPCF RDUST

ACGIH TLV: 2 MG/M3 RDUST; 9293


CALCIUM CARBONATE (MARBLE) (LIMESTONE)

CAS: 1317-65-3

RTECS: EV9580000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9192


STARCH

CAS: 9005-25-8

RTECS: GM5090000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3; 9192


MAGNESIUM CHLORIDE, ANHYDROUS

CAS: 7786-30-3

RTECS: OM2800000


NON-HAZARDOUS INGREDIENTS (INERT)

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT) IS NOT ESTABLISHED.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION OF DUST MAY CAUSE
RESPIRATORY IRRITATION. ALTHOUGH UNLIKEY, INHALATION OF FUMES FROM
HEATED MATERIAL MAY CAUSE METAL FUME FEVER. EYE CONTACT ILONGED
INHALATION OF DUST MAY LEAD TO LU NG DMAGE(PNEUMOCONIOSIS).
Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS
LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:INHALATION MAY CAUSE COUGH, MUSCLE PAINS,
CHILLS, AND NAUSEA. SYMPTOMS MAY INCLUDE COUGHING, DIFFICULTY
BREATHING, AND THE PRODUCTION OF BLACK SPUTUM. SYMPTOMS
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS
OR WITH PRE-EXISTING DISEASE INVOLVING THE EYES, SKIN, OR
RESPIRATORY TRACT MAY BE AT INCREASED RISK FROM EXPOSURE.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING GIVE CPR.
CALL A PHYSICIAN. EYE: IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER
FOR 15 MINUTES. CALL A PHYSICIAN. SKIN: WASH WITH PLENTY OF SOAP &
WATER. INDUCE VOMITING. IF CONSCIOUS, GIVE 2 GLASSES OF WATER TO
DRINK. GIVE NOTHING BY MOUTH IF UNCONSCIOUS. CALL A PHYSICIAN
IMMEDIATELY!

Fire Fighting

Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:USE CARBON DIOXIDE, FOAM, DRY CHEMICAL, OR WATER
FOG AS SUITABLE FOR SURROUNDING MATERIALS.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:WEAR PERSONAL PROTECTIVE EQUIPMENT. CAREFULLY
CLEAN UP SPILLED MATERIAL AND PLACE IN DRY CONTAINERS FOR DISPOSAL.
AVOID DUST GENERATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A DRY AREA. KEEP CONTAINERS
TIGHTLY CLOSED WHEN NOT IN USE. PROTECT CONTAINERS FROM PHYSICAL
DAMAGE.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:IF VENTILATION DOES NOT MAINTAIN INHALATION
EXPOSURES BELOW PEL(TLV), USE NIOSH/MSHA APPROVED DUST AND FUME
RESPIRATORS AS PER CURRENT 29 CFR 1910.134, INSTRUCTIONS/WARNINGS
AND NIOSH-RESPIRATOR DECIS ION LOGIC-PUBLICATION NUMBER 87.108.
Ventilation:PROVIDE SUFFICIENT GENERAL/LOCAL EXHAUST VENTILATION IN
PATTERN/VOLUME TO CONTROL INHALATION EXPOSURES BELOW OSHA'S PEL.
Protective Gloves:PROTECTIVE GLOVES (TYPE NOT SPECIFIED)
Eye Protection:SAFETY GOGGLES AS REQUIRED
Other Protective Equipment:INDUSTRIAL-TYPE WORK CLOTHING AS REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
FOOTWEAR.
Supplemental Safety and Health
DO NOT GET ON SKIN, IN EYES OR ON CLOTHING. DO NOT BREATHE DUST OR
FUMES(HEATED MATERIAL).

Chemical Properties

HCC:N1
Decomp Temp:Decomp Text:>1200F
Spec Gravity:2.56
Solubility in Water:APPRECIABLE
Appearance and Odor:GRAY TO BLACK POWDER; ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS
Hazardous Decomposition Products:HYDROGEN CHLORIDE, CHLORINE, MAGNESIUM
OXIDE FUME

Disposal

Waste Disposal Methods:DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH ALL
APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.